What it is, and what it is not

Electric underfloor heating is a thin heating element that sits in the floor build up, under the tile, warming the surface you walk on. It is a comfort system for an interior room.

It is not a frost protection system, which we go into in our notes on frost, ice and tile, it is not a replacement for a heat pump in a large open living space, and it will not rescue a cold house with poor insulation. If somebody has sold it to you as whole house heating, that is the wrong expectation and you will be disappointed by the power bill before you are disappointed by the warmth.

Where it is genuinely very good is the specific problem of a cold hard floor in a room you use barefoot.

Why it suits tile in particular

Tile is dense, and density is exactly what makes a floor feel cold underfoot. It conducts heat away from your feet faster than timber or carpet, which is why a tiled bathroom in July feels colder than the air in the room actually is.

That same density is what makes tile the best possible surface over heating. It conducts the warmth up and spreads it evenly, and it does not mind the temperature cycling. The property that makes tile cold without heating is the property that makes it excellent with it.

How quickly it actually warms up

This is the question that decides whether people use the system or resent it.

The published figures vary by system and by how deep the heating sits. For a Devimat directly beneath tiles the warm up time is given as around thirty minutes. For an in slab storage system, where the heat has to move through a thick concrete slab, it is in the range of five to seven hours.

That difference is the whole argument. Thirty minutes means you can put it on a timer for the half hour before you get up, heat the bathroom for the time you are in it, and turn it off. Five to seven hours means you are heating a slab overnight whether you need it or not. If you want a system you can switch on and feel, the mat under the tile is the one that behaves that way.

The DEVI underfloor heating range has the system detail, and the national guide to underfloor heating with tiles goes deeper into the technical side than we do here. We fit these systems in Wanaka, so come to us for the sizing and the install.

The downsides, since nobody lists them

Four things worth knowing before you commit:

  • It is a running cost, not a one off. It is electric resistance heating, so what you pay depends on the area, how long you run it and how well the floor is insulated beneath.
  • The mat cannot be trimmed to fit. The heating element must not be shortened, because changing its electrical resistance can cause overheating. You measure the free floor area and choose the nearest smaller element. That means the sizing has to be right before anything is ordered.
  • It does not go everywhere in the room. DEVI advises against running it under a bath, a shower tray or fixed kitchen units, because those restrict heat output and make any future fault repair much harder.
  • Retrofitting means lifting the floor. It lives under the tile, so adding it later is not an upgrade, it is a new floor.

None of those are reasons not to do it. They are reasons to decide at the right moment, which is before the floor is built, not after.

It has to be planned into the floor build up

This is the part that gets skipped, and it is where the installation either works or gives trouble.

The floor should be primed first, because dust and grease stop the mat adhesive backing from bonding properly. The adhesive or levelling layer over the top has to cover the cables, and the published guidance is that four to five millimetres is generally enough. Adhesives, levelling compounds and grouts should be flexible or include a flexible additive, since the floor is now going to move with temperature.

Where one floor runs across different substrates, say a section of timber and a section of concrete, the recommendation is a separate mat and thermostat for each, because the two surfaces have different maximum temperature limits. Insulation is not strictly required, since the system is designed to go on an existing floor, but where the height allows it, insulation or a tile backer board underneath improves performance and reduces what it costs to run.

And after tiling, the heating stays off until the adhesive has dried and cured naturally, following the adhesive manufacturer instructions. Rushing that stage to test the new toy is a good way to damage the floor you just paid for.

Where it earns its keep in a Central Otago house

Our honest view, from selling and fitting it here:

A bathroom or ensuite is the clearest case. Small area, used barefoot, used at the coldest times of day, and a thirty minute warm up fits the way people actually use the room. If that is the room you are working on, choosing tiles for a bathroom covers the rest of the decisions. An entry or mudroom is the second case, because it dries wet boots and melted frost rather than leaving puddles on cold tile. A kitchen floor is a reasonable case if you stand there a lot.

A large open living area is where we would tell you to think harder. The area is big, the running cost scales with it, and you may be better served putting that money into the main heating and insulation.

What we need to know to size it

Because the element cannot be cut, sizing comes first. What helps us is the free floor area, meaning the floor that is actually open and not under a bath, a shower base or fixed cabinetry, along with what the substrate is, what tile you are planning and what the floor height allows for insulation.

Bring that to the showroom on McCormick Street and we will work the sizing out with you. We supply and fit underfloor heating with the tile as one job, which matters here more than on most jobs, because the heating decision and the tile decision are really one decision made at the same moment.

If you are laying the floor yourself, our notes on where to start when tiling a floor cover the order of work, and the adhesive guide covers the flexible products this job needs. Specifying for a client? The trade page has technical backup and delivery to site.

Plan heating before selecting the floor build-up

Bring the room dimensions and tell us whether the base is concrete or timber, whether old flooring will be removed and which rooms you want heated. Our Wanaka team can discuss tile selection and heating supply and installation together; the installation quote depends on your project.

Common questions

Is underfloor heating worth it under tiles?

For a bathroom, ensuite, entry or kitchen it usually is, because those are small areas used barefoot at the coldest times of day, and a mat under tile is published as warming up in around thirty minutes. For a large open living area the running cost scales with the floor area, so it is worth comparing against spending the same money on main heating and insulation.

What are the downsides of electric underfloor heating?

It is a running cost rather than a one off, the mat cannot be shortened to fit so sizing has to be correct before ordering, it should not be run under a bath, shower tray or fixed units, and it cannot be retrofitted without lifting the floor. None of those rule it out, but all of them have to be decided before the floor is built.

How long does underfloor heating take to heat a room?

It depends on the system and how deep the heat sits. A Devimat directly under tiles is published at around thirty minutes. An in slab storage system, where heat moves through a thick concrete slab, is given as five to seven hours.

Can underfloor heating be installed under an existing tiled floor?

No. The heating element sits within the floor build up under the tile, so installing it means taking up the existing floor and laying a new one. That is why it needs to be decided at the planning stage rather than added later.